From 37b6643df2df7d784a31ca73f7bb90dc109c2401 Mon Sep 17 00:00:00 2001 From: Hans-Christoph Steiner Date: Thu, 15 Dec 2005 07:26:47 +0000 Subject: removing PDP source (except debian files) before import of PDP 0.12.4 svn path=/trunk/externals/pdp/; revision=4217 --- doc/objects/pdp_trigger.pd | 79 ---------------------------------------------- 1 file changed, 79 deletions(-) delete mode 100644 doc/objects/pdp_trigger.pd (limited to 'doc/objects/pdp_trigger.pd') diff --git a/doc/objects/pdp_trigger.pd b/doc/objects/pdp_trigger.pd deleted file mode 100644 index 2cabece..0000000 --- a/doc/objects/pdp_trigger.pd +++ /dev/null @@ -1,79 +0,0 @@ -#N canvas 218 0 631 489 10; -#X obj 46 40 pdp_help_input; -#X msg 46 10 start; -#X msg 95 10 stop; -#X obj 46 179 pdp_help_output; -#X obj 46 102 pdp_trigger; -#X text 163 98 default behaviour is to outputs bang on the right output -before sending packet to the left output; -#X obj 118 146 bng 15 250 50 0 empty empty empty 0 -6 0 8 -262144 -1 --1; -#X obj 45 269 pdp_noise; -#X obj 45 245 bng 15 250 50 0 empty empty empty 0 -6 0 8 -262144 -1 --1; -#X obj 45 294 pdp_trigger bang pdp bang bang pdp; -#X obj 45 460 print o1; -#X obj 278 326 print o5; -#X obj 161 388 print o3; -#X obj 103 429 print o2; -#X obj 219 354 print o4; -#X text 163 57 pdp_trigger behaves very much like the pd trigger object -; -#X text 162 243 you can give it pdp (p) or bang (b) arguments to send -out packets or bangs from right to left; -#X obj 365 406 pdp_t b p b b p; -#X text 325 386 there is also a short version:; -#X text 142 565 confusing note:; -#X obj 46 575 pdp_noise; -#X obj 46 551 bng 15 250 50 0 empty empty empty 0 -6 0 8 -262144 -1 --1; -#X obj 46 604 pdp_add; -#X obj 61 746 pdp_noise; -#X obj 61 722 bng 15 250 50 0 empty empty empty 0 -6 0 8 -262144 -1 --1; -#X obj 61 806 pdp_add; -#X obj 105 776 pdp_gain; -#X text 142 584 you don't need a trigger object if you connect a pdp -object's outlet to only one active inlet.; -#X text 139 657 if an outlet is connected to more than one active inlet -\, you need a trigger object like you would do with standard pd message -objects; -#X obj 285 725 pdp_noise; -#X obj 285 701 bng 15 250 50 0 empty empty empty 0 -6 0 8 -262144 -1 --1; -#X obj 285 806 pdp_add; -#X obj 343 778 pdp_gain; -#X obj 285 751 pdp_t p p; -#X floatatom 156 750 5 0 0; -#X floatatom 394 750 5 0 0; -#X text 287 829 correct; -#X text 139 852 (even more confusing note: this is because pdp uses -a 3 phase communication protocol.); -#X text 452 459 (scroll down for more); -#X text 48 829 unpredictable; -#X connect 0 0 4 0; -#X connect 1 0 0 0; -#X connect 2 0 0 0; -#X connect 4 0 3 0; -#X connect 4 1 6 0; -#X connect 7 0 9 0; -#X connect 8 0 7 0; -#X connect 9 0 10 0; -#X connect 9 1 13 0; -#X connect 9 2 12 0; -#X connect 9 3 14 0; -#X connect 9 4 11 0; -#X connect 20 0 22 0; -#X connect 20 0 22 1; -#X connect 21 0 20 0; -#X connect 23 0 25 0; -#X connect 23 0 26 0; -#X connect 24 0 23 0; -#X connect 26 0 25 1; -#X connect 29 0 33 0; -#X connect 30 0 29 0; -#X connect 32 0 31 1; -#X connect 33 0 31 0; -#X connect 33 1 32 0; -#X connect 34 0 26 1; -#X connect 35 0 32 1; -- cgit v1.2.1