#N canvas 420 106 775 605 10; #X text 129 36 write data to the (parallel) port; #X floatatom 81 304 4 0 255 0 - - -; #X text 122 304 write an 8bit-word; #X obj 90 33 lpt; #X text 521 30 part of zexy; #X text 79 64 this does not work on osX (as there is no parallel port) ; #N canvas 4 49 631 406 windows 0; #X text 32 16 To get it running under WinNT/2000/XP a special kernel driver is needed. These systems do not allow direct access to I/O ports. ; #X text 53 207 If you ever whish to remove the kernel driver start the programm again and click 'Stop'.; #X text 54 242 Under Win95/98/Me all this is not needed!!!; #X text 52 272 Good Luck!; #X text 54 141 The subfolder 'UserPort' contains a kernel driver that handles the I/O stuff. Just copy the file UserPort.sys into %WINDIR%/system32/drivers (e.g. C:/WinNT/system32/drivers) and run the program UserPort.exe. Click on 'Start' and then 'Exit'.; #X text 175 112 ftp://iem.at/DOSen/UserPort/; #X text 172 82 http://www.embeddedtronics.com/public/Electronics/minidaq/.. ../userport; #X text 49 79 downloads:; #X text 267 326 thanks to Olaf Matthes for this; #X restore 292 86 pd windows; #X text 80 253 you should be member of the "lp" group or set the the permissions of the device file; #X obj 81 477 lpt /dev/parport0; #N canvas 4 49 553 385 raw 0; #X text 24 127 if your port-address exceeds 0x3ff \, "lpt" will try to get all permissions with the iopl()-command. this might be dangerous !; #X text 26 50 you can access all ports on your system when using "lpt "; #X text 26 89 you might have to be root (superuser) \, in order to gain raw access to the port.; #X text 75 230 parallel ports 0 \, 1 \, 2; #X obj 81 251 lpt 0; #X obj 130 251 lpt 1; #X obj 179 251 lpt 2; #X obj 68 329 lpt 0x378; #X text 63 308 another port (directly specifying the port address) ; #X restore 460 150 pd raw access; #X text 78 86 w32 users shoud read this:; #X text 81 153 linux users can use the deprecated RAW access method ; #X text 80 219 you can access your parallel ports by accessing /dev/parport0 (and similar); #X text 82 189 the preferred way for linux users is to use the device-filesystem: ; #X text 217 478 <-- access /dev/parport0; #X obj 84 545 lpt /dev/parports/0; #X text 222 546 <-- some systems might use this syntax; #X msg 335 309 control \$1; #X floatatom 335 291 4 0 255 0 - - -; #X floatatom 81 509 5 0 0 0 - - -; #X msg 337 433 bang; #X text 380 437 read the input bits; #X text 131 509 input bits; #N canvas 461 150 494 344 META 0; #X text 12 145 HELP_PATCH_AUTHORS "pd meta" information added by Jonathan Wilkes for Pd version 0.42.; #X text 12 25 LICENSE GPL v2; #X text 12 125 AUTHOR IOhannes m zmoelnig; #X text 12 45 DESCRIPTION write data to the (parallel) port; #X text 12 65 INLET_0 float bang control; #X text 12 105 OUTLET_0 float; #X text 12 5 KEYWORDS control hardware interfacing; #X text 12 85 INLET_1 float; #X restore 571 557 pd META; #X floatatom 335 361 4 0 255 0 - - -; #X text 373 361 alternative way to set control bits; #X text 373 291 set control bits; #X connect 1 0 8 0; #X connect 8 0 19 0; #X connect 17 0 8 0; #X connect 18 0 17 0; #X connect 20 0 8 0; #X connect 24 0 8 1;