aboutsummaryrefslogtreecommitdiff
path: root/packages
diff options
context:
space:
mode:
authorHans-Christoph Steiner <eighthave@users.sourceforge.net>2006-01-17 16:01:41 +0000
committerHans-Christoph Steiner <eighthave@users.sourceforge.net>2006-01-17 16:01:41 +0000
commit0469267ee49a4e4b9016a4c818bddc99b4f38dbe (patch)
tree47a621296a020d7a1d425c96ab4ccf863b6002f9 /packages
parent531493b6d150abd87a38dafabe9ddff36c266a20 (diff)
made registry file clear out all old path and loadlib settings before installing the new ones. Otherwise, the previous cruft could cause problems. Yes, this might blow away settings, but it only affects loadlib and path, so the damage is limited.
svn path=/trunk/; revision=4442
Diffstat (limited to 'packages')
-rwxr-xr-xpackages/win32_inno/pd-settings.reg107
1 files changed, 107 insertions, 0 deletions
diff --git a/packages/win32_inno/pd-settings.reg b/packages/win32_inno/pd-settings.reg
index 88a668ce..a336b05c 100755
--- a/packages/win32_inno/pd-settings.reg
+++ b/packages/win32_inno/pd-settings.reg
@@ -1,6 +1,61 @@
Windows Registry Editor Version 5.00
[HKEY_LOCAL_MACHINE\SOFTWARE\Pd]
+
+;;
+;; blow away all lib settings to prevent conflicts, wrong order, etc.
+"loadlib1"=-
+"loadlib2"=-
+"loadlib3"=-
+"loadlib4"=-
+"loadlib5"=-
+"loadlib6"=-
+"loadlib7"=-
+"loadlib8"=-
+"loadlib9"=-
+"loadlib10"=-
+"loadlib11"=-
+"loadlib12"=-
+"loadlib13"=-
+"loadlib14"=-
+"loadlib15"=-
+"loadlib16"=-
+"loadlib17"=-
+"loadlib18"=-
+"loadlib19"=-
+"loadlib20"=-
+"loadlib21"=-
+"loadlib22"=-
+"loadlib23"=-
+"loadlib24"=-
+"loadlib25"=-
+"loadlib26"=-
+"loadlib27"=-
+"loadlib28"=-
+"loadlib29"=-
+"loadlib30"=-
+"loadlib31"=-
+"loadlib32"=-
+"loadlib33"=-
+"loadlib34"=-
+"loadlib35"=-
+"loadlib36"=-
+"loadlib37"=-
+"loadlib38"=-
+"loadlib39"=-
+"loadlib40"=-
+"loadlib41"=-
+"loadlib42"=-
+"loadlib43"=-
+"loadlib44"=-
+"loadlib45"=-
+"loadlib46"=-
+"loadlib47"=-
+"loadlib48"=-
+"loadlib49"=-
+
+;;
+;; load libs included with Pd-extended
"loadlib1"="Gem"
"loadlib2"="cyclone"
"loadlib3"="zexy"
@@ -27,3 +82,55 @@ Windows Registry Editor Version 5.00
"loadlib24"="unauthorized"
"loadlib25"="vbap"
"loadlib26"="xsample"
+
+;;
+;; blow away all path settings to prevent conflicts, wrong order, etc.
+"path1"=-
+"path2"=-
+"path3"=-
+"path4"=-
+"path5"=-
+"path6"=-
+"path7"=-
+"path8"=-
+"path9"=-
+"path10"=-
+"path11"=-
+"path12"=-
+"path13"=-
+"path14"=-
+"path15"=-
+"path16"=-
+"path17"=-
+"path18"=-
+"path19"=-
+"path20"=-
+"path21"=-
+"path22"=-
+"path23"=-
+"path24"=-
+"path25"=-
+"path26"=-
+"path27"=-
+"path28"=-
+"path29"=-
+"path30"=-
+"path31"=-
+"path32"=-
+"path33"=-
+"path34"=-
+"path35"=-
+"path36"=-
+"path37"=-
+"path38"=-
+"path39"=-
+"path40"=-
+"path41"=-
+"path42"=-
+"path43"=-
+"path44"=-
+"path45"=-
+"path46"=-
+"path47"=-
+"path48"=-
+"path49"=-